PPG INDUSTRIES INC (WAS PTTTSBURGH PLATE GLASS CO) -- CALCIUM HYPOCHLORITE -- 6810-00-255-0471
=====================  Product Identification  =====================

Product ID:CALCIUM HYPOCHLORITE
MSDS Date:02/01/1989
FSC:6810
NIIN:00-255-0471
=== Responsible Party ===
Company Name:PPG INDUSTRIES INC (WAS PTTTSBURGH PLATE GLASS CO)
Address:ONE PPG PLACE
City:PITTSBURGH
State:PA
ZIP:15272-0001
Country:US
Info Phone Num:412-434-3131
Emergency Phone Num:304-843-1300
Preparer's Name:R. KENNETH LEE
CAGE:47695
=== Contractor Identification ===
Company Name:CHEMICAL COMMODITIES AGENCY, INC.
Address:27447 PACIFIC STREET
Box:City:HIGHLAND
State:CA
ZIP:92346-2640
Country:US
Phone:909-864-2310
CAGE:60777
Company Name:PPG INDUSTRIES INC
Address:ONE PPG PLACE
Box:City:PITTSBURGH
State:PA
ZIP:15272
Country:US
Phone:1-800-245-2974 (CAL HYPO)
CAGE:47695
Company Name:PPG INDUSTRIES INC CHEMICAL DIVISION
Address:ONE GATEWAY CENTER
City:PITTSBURGH
State:PA
ZIP:15222-1416
Country:US
Phone:304-843-1300
CAGE:93915

=============  Composition/Information on Ingredients  =============

Ingred Name:CALCIUM HYPOCHLORITE  (SARA III) (65% AVAILABLE CHLORINE)
CAS:7778-54-3
RTECS #:NH3485000
Fraction by Wt: 65%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.5 PPM (CL)
ACGIH TLV:0.5 PPM (CL); 9394
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS

Ingred Name:INERT (INCLUDES 5.5-10% MOISTURE)
Fraction by Wt: 35%
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE ESTABLISHED BY OSHA/ACGIH FOR PROD
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHAL:TISSUE IRRIT,UPPER RESP TRACT
    IRRIT,NASAL CONGESTION,COUGH,SORE THROAT,LARYNGITIS,SHORTNESS OF
    BREATH,PULM EDEMA.SKIN:SLIGHTLY TOXIC. SKIN/EYE:CORR.SEVERE
    IRRIT,BURNS,TISSUE DESTRUCTION.INGEST:S EVERE BURNS TO DIGESTIVE
    TRACT,CAN BE FATAL,SLIGHTLY TOXIC.
Explanation of Carcinogenicity:PER MSDS:IC CHEMICAL LISTED AS
    CARCINOGEN OR POTENTIAL CARCINOGE:NTP/IARC/OSHA:NO.
Effects of Overexposure:INHAL:TISSUE & UPPER RESP TRACT IRRIT, NASAL
    CONGESTION, COUGHING, SORE THROAT, LARYNGITIS, SHORTNESS OF BREATH,
    PULMONARY EDEMA. SKIN/EYE:SEVERE IRRIT, BURNS, TISSUE DESTRUCTION.
    INGEST:SEVERE BURNS  TO DIGESTIVE TRACT, CAN BE FATAL.
Medical Cond Aggravated by Exposure:NONE KNOWN.

=======================  First Aid Measures  =======================

First Aid:INHAL:REMOVE TO FRESH AIR. NOT BREATHING GIVE ART RESP
    PREFERABLY MOUTH-TO-MOUTH. BREATH DIFFICULT GIVE OXY. CALL
    PHYSICIAN. EYE/SKIN:FLUSH W/PLENTY OF WATER FOR @LESAT 15MINS WHILE
    REMOVING CONTAMIN  CLOTH/SHOES. EYE:GET IMMED MED ATTN. SKIN IRRIT
    OCCURS GET MED ATTN. INGEST:IF CONSCIOUS DRINK LG QUANT OF WATER &
    ANY COMMON COOKING(VEG)OIL IF AVAILABLE. DO NOT INDUCE VOMIT. TAKE
    IMMED TO (SUPPLE)

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Extinguishing Media:WATER ONLY! SMOTHERING INEFFECTIVE-PRODUCT SUPPLIES
    OWN OXYGEN.
Fire Fighting Procedures:FIRE FIGHTERS MUST WEAR NIOSH/MSHA APPORVED
    PRESSURE DEMAND SELF-CONTAINED BREATHING APPARATUS W/FULL FACEPIECE
    FOR POSSIBLE EXPO TO HAZ GASES.
Unusual Fire/Explosion Hazard:DECOMPOSES @180C RELEASING OXY GAS.CNTNRS
    MAY RUPTURE.MAY CAUSE FIRE/EXPLO IF MIX W/OTHER CHEM.FIRE RESULTS
    IF CONTAM W/ACIDS/EASILY COMBUST MATL(ORG MATL,ETC).

==================  Accidental Release Measures  ==================

Spill Release Procedures:USE EXTREME CAUTION IN HANDLING.CONTAMIN
    W/ORG/COMBUST MATL MAY CAUSE FIRE/VIOLENT DECOMP;IF SO IMMED DOSE
    W/PLENTY OF WATER.OTHERWISE SWEEPUP ALL VISIBLE MATL W/CLEAN DRY
    SHOVEL/BROOM.DISSOLVE MATL I N WATER.DISPOSE OF WASTE MATL
    ACCORDINGLY.
Neutralizing Agent:HYDROGEN PEROXIDE (1 PT OF 35% H2O2 PER 1 LB OF
    CALCIUM HYPOCHLORITE).

======================	Handling and Storage  ======================

Handling and Storage Precautions:DON'T GET IN EYES/SKIN/CLOTH.KEEP IN
    ORIGINAL CNTNR IN COOL DRY PLACE & CLSD WHEN NOT IN USE.KEEP AWAY
    FRM HEAT SOURCES/SPARKS/LIGHTED TOBACCO PRODUCT
Other Precautions:USE ONLY CLEAN DRY METAL/PLASTIC SCOOP EACH TIME PROD
    TAKEN FRM CNTNR.DON'T ADD PROD TO DISPERNSING DEVICE HAVING
    REMNANTS OF OTHER MATL.SAFE HANDL OF MATL ON LONG-TERM BASIS SHOULD
    EMPHASIZE MIN REPE ATED ACUTE EXPO.AQUATIC:HIGHLY TOX.(SUP)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF DUSTY CONDITONS ENCOUNTERED USE NIOSH/MSHA
    APPROVED RESP W/ACID GAS CARTRIDGE & DUST PREFILTER.RESP USE
    LIMITATIONS SPECIFIED BY NIOSH/MSHA OR MFG MUST BE OBSERVED.RESP
    PROTECTION PROGRAMS MUST BE  IAW 29CFR1910.134.
Ventilation:NONE, UNLESS DUSTY CONDITIONS ARE ENCOUNTERED.
Protective Gloves:NATURAL OR SYNTHETIC RUBBER
Eye Protection:CHEMICAL LSAFETY GOGGLES
Other Protective Equipment:USE BOOTS,APRONS,CHEM SUITS WHEN NECESSARY
    TO PREVENT SKIN CONTACT.PERSONAL PROT CLOTH/EQPMT IAW 29CFR1910.134
    & 133.
Work Hygienic Practices:WASH HANDS AFT HANDLING.FATAL/HARMFUL IF
    INGEST.MAY CAUSE CHEM BURNS.IRRIT TO NOSE/THROAT-AVOID BREATHING
    DUST.
Supplemental Safety and Health
PH OF SOLN:ALKALINE. 1STAID:HOSPITAL/PHYSICIAN.DO NOT ATTEMPT TO INDUCE
    VOMIT OR GIVE ANYTHING BY MOUTH IF UNCONSC.NOTE TO DR:TREAT
    SYMPTOMATICALLY. OTHER PRECAUT:ADD PROD ONLY TO WATER.DON'T REUSE
    CN TNR.KEEP OUT OF CHILDREN.PROD REGISTERED W/EPA AS PESTICIDE.

==================  Physical/Chemical Properties  ==================

HCC:D1
Boiling Pt:B.P. Text:DECOMP@180C
Decomp Temp:Decomp Text:356F,180C
pH:SUPPLE
Solubility in Water:217G/L @27C
Appearance and Odor:WHITE POWDER WITH SLIGHT CHLORINE ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:NO
ACIDS, BOMSUTIBLE MATLS, ORGANICS, REDUCING AGENTS.
Stability Condition to Avoid:CONTAMINATION OR EXCESSIVE HEAT ABOVE
    177C.
Hazardous Decomposition Products:ACIDS OR AMMONIA CONTAMIN RELEASES TOX
    GASES.EXCESSIVE HEAT WILL CAUSE DECOMP RESULTING IN RELEASE OF OXY
    & CHLORINE GAS

====================  Disposal Considerations  ====================

Waste Disposal Methods:SPILLED MATL DISSOLVED IN WATER SHOULD BE USED
    IMMED IN NORMAL APPLICATION FOR WHICH MATL BEING CONSUMED.IF NOT
    NEUTRALIZE W/HYDROGEN PEROXIDE(1PT 35%H2O2 PER LB PRODUCT).DILUTE
    W/PLENTY OF WATER.FLUS H TO SEWER.DISPOSE OF IAW ALL APPLICABLE
    REGS/LAW.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.