MALLINCKRODT INC -- HYDROFLUORIC ACID 48% -- 6810-00-237-2920
===================== Product Identification =====================
Product ID:HYDROFLUORIC ACID 48%
MSDS Date:01/01/1985
FSC:6810
NIIN:00-237-2920
=== Responsible Party ===
Company Name:MALLINCKRODT INC
Address:675 MCDONNELL BLVD
Box:5840
City:SAINT LOUIS
State:MO
ZIP:63134
Country:US
Info Phone Num:314-539-1600
Emergency Phone Num:314-539-1600
CAGE:37940
=== Contractor Identification ===
Company Name:MALLINCKRODT INC
Address:675 MCDONNELL BLVD
Box:5840
City:ST. LOUIS
State:MO
ZIP:63134
Country:US
Phone:314-539-1600
CAGE:37940
============= Composition/Information on Ingredients =============
Ingred Name:HYDROGEN FLUORIDE (SARA III)
CAS:7664-39-3
RTECS #:MW7875000
Fraction by Wt: 48%
OSHA PEL:3 PPM/6 STEL (F)
ACGIH TLV:C 3 PPM (F); 9192
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Ingred Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: 52%
======================= First Aid Measures =======================
First Aid:SPEED IN REMOVING PATIENT FROM CONTAMINATED ATMOSPHERE AND
REMOVING ACID FROM SKIN OR EYES IS VERY IMPORTANT. FLUSH SKIN WITH
PLENTY OF WATER-USE SHOWER.IRRIGATE EYES IMMEDIATELY WITH WATER FOR
15-30 MINUTES. GET MEDICAL HELP.
===================== Fire Fighting Measures =====================
Fire Fighting Procedures:SEE SUPPLEMENTAL DATA. WEAR SPECIAL PROTECTIVE
CLOTHING.
Unusual Fire/Explosion Hazard:LIQUID;VAPORS ARE CORROSIVE AND WILL
ATTACK STEEL AND OTHER METALS TO GENERATE EXPLOSIVE HYDROGEN.
================== Accidental Release Measures ==================
Spill Release Procedures:GOOD VENTILATION IS A NECESSITY. FLUSH SPILLS
AWAY WITH WATER IMMEDIATELY.NEUTRALIZE RESIDUE WITH LIME AND AGAIN
WASH WITH WATER. NEUTRALIZING WITH LIMESTONE WILL RELEASE CARBON
DIOXIDE GAS.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT CONTACT GLASS,CERAMIC OR OTHR
SILICA CONTAINING MATERIAL OR CONTAINERS AS REACTION IS RAPID WITH
HEAT AND GAS EVOLUTION.
Other Precautions:PROTECT AGAINST PHYSICAL DAMAGE. STORE IN
WELL-VENTILATED AREA,SEPARATED FROM OTHER STORAGE.WEAR NEOPRENE
GLOVES,FULL FACE SHIELD, PLASTIC COVERALLS,FACE MASK WITH CANISTER.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:U.S.BUREAU OF MINES APPROVED SELF-CONTAINED OR
AIR SUPPLIED BREATHER
Ventilation:LOCAL-YES
Protective Gloves:RUBBER NEOPRENE
Eye Protection:SAFETY GOGGLES
Other Protective Equipment:FULL FACE MASK,FULL COVERAGE OF
CLOTHING,RUBBER SHOES
Supplemental Safety and Health
THE AMOUNT OF HYDROFLUORIC ACID VAPORS RELEASED FROM RUPTURED
CONTAINERS WILL INCREASED BY HEAT. DILUTION WITH WATER WILL
GENERATE HEAT AND ALSO INCREASE CORROSION ON STEEL CONTAINERS.
================== Physical/Chemical Properties ==================
HCC:C1
Boiling Pt:B.P. Text:152
Vapor Pres:130
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS LIQUID,SHARP ACIDIC ODOR,FUMES IN AIR
================= Stability and Reactivity Data =================
GLASS,CONCRETE,CERTAIN METALS,NATURAL RUBBER, MANY ORGANICS.
Hazardous Decomposition Products:HYDROFLUORIC ACID GAS
Conditions to Avoid Polymerization:HYDROGEN FLUORID VAPORS RELEASED
FROM UNCONFINED ACID.
==================== Disposal Considerations ====================
Waste Disposal Methods:NEUTRALIZE AS ABOVE WITH LIME OR LIMESTONE AND
BURY IN APPROVED AREAS,IF PERMISSABLE FLUORIDE SALTS ARE TOXIC AND
DISPOSAL BY A DISPOSAL CONTRACTOR MAY BE REQUIRED.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.