MALLINCKRODT INC -- HYDROFLUORIC ACID 48% -- 6810-00-237-2920
===================== Product Identification ===================== Product ID:HYDROFLUORIC ACID 48% MSDS Date:01/01/1985 FSC:6810 NIIN:00-237-2920 === Responsible Party === Company Name:MALLINCKRODT INC Address:675 MCDONNELL BLVD Box:5840 City:SAINT LOUIS State:MO ZIP:63134 Country:US Info Phone Num:314-539-1600 Emergency Phone Num:314-539-1600 CAGE:37940 === Contractor Identification === Company Name:MALLINCKRODT INC Address:675 MCDONNELL BLVD Box:5840 City:ST. LOUIS State:MO ZIP:63134 Country:US Phone:314-539-1600 CAGE:37940 ============= Composition/Information on Ingredients ============= Ingred Name:HYDROGEN FLUORIDE (SARA III) CAS:7664-39-3 RTECS #:MW7875000 Fraction by Wt: 48% OSHA PEL:3 PPM/6 STEL (F) ACGIH TLV:C 3 PPM (F); 9192 EPA Rpt Qty:100 LBS DOT Rpt Qty:100 LBS Ingred Name:WATER CAS:7732-18-5 RTECS #:ZC0110000 Fraction by Wt: 52% ======================= First Aid Measures ======================= First Aid:SPEED IN REMOVING PATIENT FROM CONTAMINATED ATMOSPHERE AND REMOVING ACID FROM SKIN OR EYES IS VERY IMPORTANT. FLUSH SKIN WITH PLENTY OF WATER-USE SHOWER.IRRIGATE EYES IMMEDIATELY WITH WATER FOR 15-30 MINUTES. GET MEDICAL HELP. ===================== Fire Fighting Measures ===================== Fire Fighting Procedures:SEE SUPPLEMENTAL DATA. WEAR SPECIAL PROTECTIVE CLOTHING. Unusual Fire/Explosion Hazard:LIQUID;VAPORS ARE CORROSIVE AND WILL ATTACK STEEL AND OTHER METALS TO GENERATE EXPLOSIVE HYDROGEN. ================== Accidental Release Measures ================== Spill Release Procedures:GOOD VENTILATION IS A NECESSITY. FLUSH SPILLS AWAY WITH WATER IMMEDIATELY.NEUTRALIZE RESIDUE WITH LIME AND AGAIN WASH WITH WATER. NEUTRALIZING WITH LIMESTONE WILL RELEASE CARBON DIOXIDE GAS. ====================== Handling and Storage ====================== Handling and Storage Precautions:DO NOT CONTACT GLASS,CERAMIC OR OTHR SILICA CONTAINING MATERIAL OR CONTAINERS AS REACTION IS RAPID WITH HEAT AND GAS EVOLUTION. Other Precautions:PROTECT AGAINST PHYSICAL DAMAGE. STORE IN WELL-VENTILATED AREA,SEPARATED FROM OTHER STORAGE.WEAR NEOPRENE GLOVES,FULL FACE SHIELD, PLASTIC COVERALLS,FACE MASK WITH CANISTER. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:U.S.BUREAU OF MINES APPROVED SELF-CONTAINED OR AIR SUPPLIED BREATHER Ventilation:LOCAL-YES Protective Gloves:RUBBER NEOPRENE Eye Protection:SAFETY GOGGLES Other Protective Equipment:FULL FACE MASK,FULL COVERAGE OF CLOTHING,RUBBER SHOES Supplemental Safety and Health THE AMOUNT OF HYDROFLUORIC ACID VAPORS RELEASED FROM RUPTURED CONTAINERS WILL INCREASED BY HEAT. DILUTION WITH WATER WILL GENERATE HEAT AND ALSO INCREASE CORROSION ON STEEL CONTAINERS. ================== Physical/Chemical Properties ================== HCC:C1 Boiling Pt:B.P. Text:152 Vapor Pres:130 Solubility in Water:COMPLETE Appearance and Odor:COLORLESS LIQUID,SHARP ACIDIC ODOR,FUMES IN AIR ================= Stability and Reactivity Data ================= GLASS,CONCRETE,CERTAIN METALS,NATURAL RUBBER, MANY ORGANICS. Hazardous Decomposition Products:HYDROFLUORIC ACID GAS Conditions to Avoid Polymerization:HYDROGEN FLUORID VAPORS RELEASED FROM UNCONFINED ACID. ==================== Disposal Considerations ==================== Waste Disposal Methods:NEUTRALIZE AS ABOVE WITH LIME OR LIMESTONE AND BURY IN APPROVED AREAS,IF PERMISSABLE FLUORIDE SALTS ARE TOXIC AND DISPOSAL BY A DISPOSAL CONTRACTOR MAY BE REQUIRED. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.