PENNZOIL CO -- 7450,7440,7460;JET SPRAY,GUMOUT CARBURETOR AND CHOKE CLEANER -- 6850-01-085-1423
===================== Product Identification =====================
Product ID:7450,7440,7460;JET SPRAY,GUMOUT CARBURETOR AND CHOKE CLEANER
MSDS Date:04/15/1998
FSC:6850
NIIN:01-085-1423
=== Responsible Party ===
Company Name:PENNZOIL CO
Address:700 MILIAM PENNZOIL PL
Box:2967
City:HOUSTON
State:TX
ZIP:77252
Country:US
Info Phone Num:713-546-4000/6227; FAX -4876
Emergency Phone Num:713-236-6070
Preparer's Name:ENV SAFETY AND HEALTH
CAGE:01326
=== Contractor Identification ===
Company Name:PENNZOIL CO
Address:700 MILIAM PENNZOIL PL
Box:2967
City:HOUSTON
State:TX
ZIP:77252-2967
Country:US
Phone:800-546-6227
CAGE:01326
Company Name:PHOENIX INDUSTRIES INC
Address:1519 CHAMBERLAYNE PARKWAY
Box:City:RICHMOND
State:VA
ZIP:23222
Country:US
Phone:804-264-5183/FAX: 264-5535
CAGE:0YED2
============= Composition/Information on Ingredients =============
Ingred Name:NAPHTHA, LIGHT AROMATIC (SOLVENT NAPHTHA)
CAS:64742-95-6
RTECS #:WF3400000
Fraction by Wt: 30-50%
Other REC Limits:500 PPM
Ingred Name:HYDROTREATED LIGHT DISTILLATE OR PETROLEUM HYDROCARBON
CAS:64742-47-8
RTECS #:OA5504000
Fraction by Wt: 10-30%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:5 MG/M3 (OIL MIST)
ACGIH TLV:5 MG/M3 (OIL MIST)
Ingred Name:METHYL ETHYL KETONE (2-BUTANONE) (MEK) (SARA 313) (CERCLA)
CAS:78-93-3
RTECS #:EL6475000
Fraction by Wt: 1-7%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:200 PPM
ACGIH TLV:200 PPM/300STEL;9596
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:ISOPROPYL ALCOHOL (SARA 313)
CAS:67-63-0
RTECS #:NT8050000
Fraction by Wt: 1-7%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:400 PPM
ACGIH TLV:400 PPM/500STEL;9596
Ingred Name:PROPANE
CAS:74-98-6
RTECS #:TX2275000
Fraction by Wt: 15-25%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:ASPHYXIANT; 9596
Ingred Name:SURFACTANTS (TYPE NOT SPECIFIED)
Fraction by Wt: <1%
Other REC Limits:NONE RECOMMENDED
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES CONTACT MAY CAUSE IRRITATION &
CORNEAL BURNS.SKIN CONTACT MAY CAUSE IRRITATION,
DERMATITIS.INGESTION OF SMALL QUANTITIES IS NON-FATAL UNLESS
ASPIRATION OCCURS.INHALATION MAY CAUSE RESPIRATORY IRR ITATION &
ANESTHETIC EFFECTS. CHRONIC:PROLONGED/REPEATED EXPOSURE MAY DAMAGE
LIVER, KIDNEYS,BLOOD,SPLEEN AND ADRENALS.
Explanation of Carcinogenicity:ISOPROPANOL HAS BEEN CLASSIFIED
IARC-3(NOT CLASSIFIABLE AS TO CARCINOGENICITY).
Effects of Overexposure:EYES:TWITCHING,REDNESS.SKIN:DRYNESS,
CHAPPING,REDNESS.INHAL:REDDENING OF THE FACE AND A FELLING OF
INCREASED BODY HEAT,DISTURBED
VISION,DIZZINESS,TREMORS,SALIVATION,CARDIAC STRESS,
DROWSINESS,DULLNESS
,NUMBNESS,WEAKNESS,HEADACHE,NAUSEA,CONFUSION,DIFFICULTY
BREATHING.ASPIRATION:HEMORRAGE,SKIN DISCOLORATION,COUGHING,CHOKI
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:IN ALL CASES GET MEDICAL ATTENTION. EYES-FLUSH WITH WATER FOR
15 MINUTES. SKIN-WASH WITH MILD SOAP & WATER. USE HAND LOTION TO
PREVENT DRYNESS. INHALED-REMOVE TO FRESH AIR. GIVE OXYGEN OR
ARTIFICIAL R ESPIRATION AS NEEDED. INGESTED-DO NOT INDUCE VOMITING!
IF VOMITING OCCURS, LOWER HEAD BELOW KNEES.
===================== Fire Fighting Measures =====================
Extinguishing Media:WATER FOG, CARBON DIOXIDE, DRY CHEMICAL, FOAM.
WATER MAY BE INEFFECTIVE BUT MAY BE USED TO COOL CONTAINERS.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
FULL FIRE FIGHTER'S PROTECTIVE GEAR. USE WATER TO COOL FIRE EXPOSED
CONTAINERS.
Unusual Fire/Explosion Hazard:DENSE SMOKE MAY BE GENERATED WHILE
BURNING. CARBON MONOXIDE & CARBON DIOXIDE, OTHER OXIDES MAY
GENERATED AS BY-PRODUCTS OF COMBUSTION. CONTENTS UNDER PRESSURE!
================== Accidental Release Measures ==================
Spill Release Procedures:CONTAIN SPILL. WEAR APPROPRIATE PERSONAL
PROTECTIVE EQUIPMENT. KEEP OUT OF SEWERS, WATERWAYS, ETC. ELIMINATE
ALL SOURCES OF IGNITION. ENSURE ADEQUATE VENTILATION. ABSORB WITH
INERT MATERIAL & PLACE IN A CONTAINER FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE AT TEMPERATURES BELOW 120F.
FOLLOW LABEL DIRECTIONS. ALL IGNITION SOURCES IN AREA SHOULD BE
CONTROLLED.
Other Precautions:CONTENTS UNDER PRESSURE AND CAN EXPLODE WHEN EXPOSED
TO HEAT OR OPEN FLAME. DO NOT PUNCTURE OR INCINERATE. KEEP FIRE
EXTINGUISHER AVAILABLE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE SPECIFIED BY MANUFACTURER. IF ENGINEERING
CONTROLS FAIL OR NON-ROUTINE USE OR AN EMERGENCY OCCURS; WEAR AN
MSHA/NIOSH APPROVED RESPIRATOR OR AN AIR-SUPPLIED RESPIRATOR OR
SCBA, AS REQUIRED. USE I AW 29 CFR 1910.134.
Ventilation:USE ADEQUATE MECHANICAL VENTILATION OR LOCAL EXHAUST TO
MAINTAIN EXPOSURE BELOW TLV(S).
Protective Gloves:RUBBER OR IMPERVIOUS.
Eye Protection:CHEMICAL SPLASH GOGGLES
Other Protective Equipment:PROVIDE A LOCAL EYE WASH STATION AND SAFETY
SHOWER.
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
HCC:V3
Boiling Pt:B.P. Text:<-20F,<-29C
Vapor Pres:2458
Vapor Density:3-5
Spec Gravity:0.84
Evaporation Rate & Reference:>1 ETHYL ETHER=1
Solubility in Water:EMULSIFIES
Appearance and Odor:AEROSOL.LIQUID IS CLEAR, STRAW COLORED. ODOR NOT
REPORTED.
Percent Volatiles by Volume:72
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:NONE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
==================== Disposal Considerations ====================
Waste Disposal Methods:IF SPILLED OR DISCARDED, MAY BE RCRA WASTE.
REFER TO LOCAL, STATE AND FEDERAL REGULATIONS. WASTE MATERIAL MAY
BE LANDFILLED OR INCINERATED AT AN APPROVED FACILITY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.